Humidity Controlled Chamber We are instrumental in manufacturing and exporting a sturdily constructed array of Humidity Control Chamber which is manufactured using latest technology and excellent quality materials sourced from dependable suppliers of the market. To ensure high functionality and optimum efficiency, our technicians fabricate the entire range of Humidity Controlled Chamber under the supervision of stringent quality controllers. Our Humidity Controlled Chamber is compact in size, resistant to corrosion & high temperature and has a longer service life. For conditions as per ICH Guidelines
- 25oC - 60% RH/40oC - 75%RH/30oC - 65%RH / 25oC - 40% RH / 40oC - 25% RH / 30oC - 35% RH.
- Temperature range: 10.0oC to 60.0oC. Accuracy / Uniformity: +0.1oC/+1oC
- Humidity range: 25% to 95% RH. Accuracy / Uniformity +2%RH/+3%RH
- Temperature / Humidity display: Digital LED 3 1/2 digit
- Control: Microprocessor based PID control. With Auto tune CE marked
- Resolution: 0.1oC/1%RH
- Temperature sensor: PT - 100
- RH sensor: Direct capacitance type
- Heating: 'U' shaped Nichrome wire heater in SS sheathing
- Cooling: CFC free Copeland make compressor utilizing R 134A eco friendly refrigerant, with condenser, motor and relay
- Steam injection: Boiler with reservoir made of thick stainless steel, with heater, water inlet control, low water level safeguard
- Air circulation: Flange motor with impeller / blower
- Construction: Double wall, with insulation, outer door key lockable, inner glass viewing door
- Chamber illumination: Fluorescent light with door switch
- Safety features
- High temperature safety cut off
- Low water level boiler cut off
- Electrical overload cutoff relay for compressor
- Time delay for compressor switch ON
- Electrical circuit breaker
- Feet: Castor wheels. Trays: SS wire mesh heavy duty
- Electrical: 230V / 15A / 50 Hz
- Calibration certificate by ERTL - Mumbai with traceability to NPL - New Delhi
Pre Installation Mandatory Requirement: (Guarantee void incase of non compliance)
- Distilled water OR DM water continuous supply with tap for boiler input of 1/2" BSP at 3 feet height
- Room temperature around machine preferably at 25oC with air conditioning or a well ventilated room with exhaust fan. However surrounding temperature should not exceed 30oC
- Stabilized input voltage of 230V AC 20 Amps. Use of servo controlled stabilizer is recommended
- Water drain line with 1/2" nozzle to be provided at floor level
STD Model
- Outer cabinet mild steel powder coated
- Inner chamber stainless steel 304 grade
GMP Model
- Outer cabinet SS 304 grade dull matt finish
- Inner chamber stainless steel mirror finish
- With DQ, IQ, OQ documentation
Technical Specifications
|
Capacity
|
Internal Size
|
External Size
|
Shelves
|
Shpg Wt in kgs
|
|
Cu.ft
|
Liters
|
W x D x H cm
|
W x D x H cm
|
(SS)
|
|
|
4
|
120
|
45 x 45 x 60
|
65 x 114 x 130
|
2
|
200
|
|
8
|
200
|
60 x 60 x 60
|
79 x 121 x 130
|
2
|
240
|
|
12
|
324
|
60 x 60 x 90
|
79 x 121 x 165
|
3
|
250
|
|
16
|
450
|
60 x 60 x 125
|
79 x 121 x 199
|
4
|
265
|
|
21
|
600
|
60 x 60 x 155
|
79 x 121 x 247
|
5
|
295
|
|
28
|
800
|
80 x 80 x 125
|
99 x 141 x 199
|
5
|
325
|
|
34
|
1000
|
80 x 80 x 155
|
99 x 141 x 247
|
5
|
375
|
Optional Extras / Accessories
- PLC based system: PLC with HMI 3.7" touch screen grey monitor with 21 CFR Part 11 features (OSLOG) software
- Magnetic door lock feature
- GSM system: alarms sent to predefined mobile numbers
- HMI: 5.7" touch screen grey in lieu of 3.7"
- Digital PID controller with printer interface to connect EPSON Dot matrix line printer. Print interval programmable, can print date, time, temperature
- PC interface for above controller with software on CD & hardware or software with 21 CFR part 11 features
- Imported RH sensor European make, Rotronic Switzerland for higher accuracy
- Standby humidity system (except for 52 and 120 liters)
- Standby refrigeration system (except for 52 and 120 liters)
- Data logger: 4 point temp. + 4 point humidity data logger with sensors placed at specific points in chamber with printer interface and memory of 5000 readings per channel
- PC interface for above controller with software on CD & hardware
Temperature Mapping Humidity Controlled Chamber: Performance qualification with temperature and humidity mapping on site. Temperature mapping consist of one cycle at any one temperature and humidity point for a 24 hours period. This is done to demonstrate the uniformity of temperature and humidity within the chamber is acceptable and that the samples within the chamber receive a uniform temperature and humidity condition. Data is collected in printed format from up to eight different points (i.e. six temperature points and two humidity points) within the chamber. Temperature uniformity is considered acceptable if the deviation is less +1oC of set temperature. Humidity uniformity is considered acceptable if the deviation is within + 3% of set humidity.
|